FW: elution from PVDF or NC

From: Robert Moritz (Robert.Moritz@ludwig.edu.au)
Date: Mon Mar 20 2000 - 06:13:57 EST


Dear Panagiotis,
    Try the following reference.
 
 WARD, LD, REID, GE, MORITZ, RL, SIMPSON, RJ

 STRATEGIES FOR INTERNAL AMINO-ACID-SEQUENCE ANALYSIS OF PROTEINS SEPARATED
BY POLYACRYLAMIDE-GEL ELECTROPHORESIS

 JOURNAL OF CHROMATOGRAPHY

P 199 - 216

PY 1990

PD OCT 19

VL 519

IS 1

 

Best of luck.

Robert Moritz
Chief Research Officer
Joint Protein Structure Laboratory,
Ludwig Institute for Cancer Research,
P.O. Box 2008, Royal Melbourne Hospital
Parkville, Victoria,
Australia 3050
Phn +61-3-9341-3155
Fax +61-3-9341-3192

-----Original Message-----
From: Panagiotis Stasinakis [mailto:pstasina@mail.pasteur.gr]
Sent: Monday, March 20, 2000 2:55 AM
To: Recipients of ABRF List
Subject: elution from PVDF or NC

Hi there!!!
I am wondering if is possible to elute a protein from a PVDF or NC
(nitrocellulose) membrane. If there is a specific way or protocol i would pe
grateful if you could inform me about this.
 
Thanks!!!
 
Panagiotis Stasinakis
Phd student
Hellenic Institute Pasteur
Departement of Biochemistry
GR 11521, Athens
Greece
pstasina@mail.pasteur.gr <mailto:pstasina@mail.pasteur.gr>
pstasinar@mailhost.bio.auth.gr <mailto:pstasinar@mailhost.bio.auth.gr>
+030 01 6478840



This archive was generated by hypermail 2b29 : Mon Mar 27 2000 - 11:29:47 EST